Factory fit 01

1. Fit the window brackets to the outer-frame internal or external rib position – depending on the throw required, with the fixed pivot to the top with Yale logo the correct way up

2. Brackets are to be located 150mm from the top and bottom of the outer frame and any transom leaving no greater distance than 600mm between each bracket.

3. Where bracket fitting position aligns with outer frame steel reinforcement, secure using 3.9mm diameter pan head drill point screws (or specialist equivalent) of an appropriate length. If the bracket fitting position does not align with the outer frame steel reinforcement, secure using 4.8mm  diameter pan head drill point screws of an appropriate length.

4. Place the window into the timber frame, setting the position from the top of the aperture. Ensure that the L section bracket sits square against the external face of the timber frame.

5. Set the top of the window 7mm from the top of the timber frame aperture.

Factory fit 03 rotated
Factory fit 04

6. Ensure to set leaving a minimum of 10mm from each side of the timber frame aperture to the window.

7. Secure brackets to timber frame using 4.8 x 38mm countersunk pierce point fixing screws through each of the L-shaped fixing brackets.

8. The window will sit within the timber frame for protection. Fit the 4.8 x 38mm countersunk pierce point retaining screws to prevent movement during transportation.

9. Handles and SlotVents can be factory-fitted if preferred.

NOTE: Where windows are greater than 1200mm in height, additional window brackets will need to be fitted with no greater distance than 600mm between each bracket

Fixing Summary

  • Bracket to Window aligned with steel reinforcement – 3.9mm pan head drill point
  • Bracket to Window not aligned with steel reinforcement – 4.8mm pan head
  • Bracket to Timber Frame – 4.8 x 38mm countersunk pierce point
  • Retaining screw – 4.8 x 38mm countersunk pierce point
Factory fit 05